Contact Us Mon-Fri 7am to 6pm, Sat 8:30am to 12pm
ex. VAT inc. VAT Register Sign In
OTDC200E11
OTDC200E11

DC SWITCH 2P 200A 1000VDC

My Part Number:

Part Number: OTDC200E11

Manufacturer Code: 1SCA125626R1001

Multiples of: 1 | Minimum Order: 1

View Technical Documents
Currently out of stock - available to back order

OTDC200E11 DC Switch-disconnector, Terminal bolt kit included, Handle and shaft need to be ordered separately, Base mounting, IEC 1000 VDC 200 A


Technical
Connection Configuration: Single circuit 2a, 2b
Conventional Free-air Thermal Current (Ith): Θ = 40 °C 200 A
Conventional Thermal Current (Ithe): Fully Enclosed 200 A
Degree of Protection: Front IP20
Handle Type: Handle and shaft not included
Mounting Type: Base mounting
Number of Circuits: 1
Number of Poles: 2P
Operating Mode: Front Operated
Pollution Degree: 3
Position of Line Terminals: Top In - Bottom Out, Bottom In - Top Out
Positive Opening Operation Torque (Direct Opening Action): 5 … 8 N·m
Power Loss: at Rated Operating Conditions per Pole 6 W
Rated Impulse Withstand Voltage (Uimp): 12 kV
Rated Insulation Voltage (Ui): 1500 V
Rated Operational Current DC-21B (Ie): (1000 V) 200 A
Rated Operational Voltage: 1000 V
Rated Short-Circuit Making Capacity (Icm): (1000 V DC) 10 kA
Rated Short-time Withstand Current Low Voltage (Icw): (1000 V DC) 10 kA, for 1 s 5 kA, for 0.1 s 10 kA
Shaft Diameter: 6 mm, 0.24 in
Special Functions: No
Standards: IEC 60947-1, -3
Switches Operating Mechanism: Mechanism Between the Poles, 11 (Between the Poles)
Terminal Type: Lug terminals
Terminal Width: 19.5 mm, 0.77 in
Utilization: Photovoltaic
Utilization Category: Switching of resistive loads, including moderate overloads - occasional actuation (DC-21B)

There are currently no videos available for this product
Brand
ABB

£481.00

per 1 (ex. VAT)

£577.20

per 1 (inc. VAT)
Quantity:

OTDC200E11 DC Switch-disconnector, Terminal bolt kit included, Handle and shaft need to be ordered separately, Base mounting, IEC 1000 VDC 200 A


Technical
Connection Configuration: Single circuit 2a, 2b
Conventional Free-air Thermal Current (Ith): Θ = 40 °C 200 A
Conventional Thermal Current (Ithe): Fully Enclosed 200 A
Degree of Protection: Front IP20
Handle Type: Handle and shaft not included
Mounting Type: Base mounting
Number of Circuits: 1
Number of Poles: 2P
Operating Mode: Front Operated
Pollution Degree: 3
Position of Line Terminals: Top In - Bottom Out, Bottom In - Top Out
Positive Opening Operation Torque (Direct Opening Action): 5 … 8 N·m
Power Loss: at Rated Operating Conditions per Pole 6 W
Rated Impulse Withstand Voltage (Uimp): 12 kV
Rated Insulation Voltage (Ui): 1500 V
Rated Operational Current DC-21B (Ie): (1000 V) 200 A
Rated Operational Voltage: 1000 V
Rated Short-Circuit Making Capacity (Icm): (1000 V DC) 10 kA
Rated Short-time Withstand Current Low Voltage (Icw): (1000 V DC) 10 kA, for 1 s 5 kA, for 0.1 s 10 kA
Shaft Diameter: 6 mm, 0.24 in
Special Functions: No
Standards: IEC 60947-1, -3
Switches Operating Mechanism: Mechanism Between the Poles, 11 (Between the Poles)
Terminal Type: Lug terminals
Terminal Width: 19.5 mm, 0.77 in
Utilization: Photovoltaic
Utilization Category: Switching of resistive loads, including moderate overloads - occasional actuation (DC-21B)

There are currently no videos available for this product
Brand
ABB