Contact Us Mon-Fri 7am to 6pm, Sat 8:30am to 12pm
ex. VAT inc. VAT Register Sign In
12261885111
12261885111

SERIES ELLK-NE, EX FLUORESCENT LINEAR EMERGENCY LIGHT - 220 - 254V AC FOR ZONES 1, 2, 21 & 22

My Part Number:

Part Number: 12261885111

Multiples of: 1 | Minimum Order: 1

View Technical Documents
ATEX
IECEX
Currently out of stock - available to back order

Ex-fluorescent emergency light fitting eLLK 92 036/36 NE 2/6-2 M20 metal thread

Features
• Standard dual channel ballast with EOL monitoring
• Automatic weekly 5 minute function test
• Automatic quarterly partial duty cycle test
• LED display for indication of the charging, operation or
fault status
• Capacity-dependent charging of the battery
• Easy replacement of battery, even in Ex-area
• Double-sided central locking facility
• Safety interlocking system due to an integrated forced
isolating switch
• Safety standard IP66

There are currently no videos available for this product
Brand
CEAG CROUSE HINDS
Height
1500 mm
Width
188 mm
Depth
130 mm
Weight
12 kg
IP Rating
IP66
Body Material
GRP
Minimum Operating Temperature
-20 °C
Maximum Operating Temperature
50 °C
ATEX Approval - Dust
Ex tb IIIC T80°C Db
ATEX Approval - Gas
Ex de mb ib IIC T4 Gb
Hazadrous Area Certification
1, 2, 21, 22
Approvals
ATEX, IECEx
ATEX Certificate Number
BVS 09 ATEX E 034, IECEx BVS 09.0033
Cable Entry Method
Internal Brass ECP
Emergency Output
1.5 Hours, 3 Hours
Lens Colour
Clear
Number Of Earth Terminals
1
Number Of Terminals
5
Voltage Rating
230 V AC
Colour
Light Grey
Size Reference
1200 mm, 4 Ft
Rated Frequency
50 Hz, 60 Hz
Wiring
Loop In Loop Out, Through Wired
Light Source
Fluorescent
Cable Entries
4 x M20
Nominal Output
2 x 36 W
Maximum Conductor Size
6 mm²
Additional Features
Emergency Mode: Maintained or Non-Maintained

£3,080.43

per 1 (ex. VAT)

£3,696.52

per 1 (inc. VAT)
Quantity:

Ex-fluorescent emergency light fitting eLLK 92 036/36 NE 2/6-2 M20 metal thread

Features
• Standard dual channel ballast with EOL monitoring
• Automatic weekly 5 minute function test
• Automatic quarterly partial duty cycle test
• LED display for indication of the charging, operation or
fault status
• Capacity-dependent charging of the battery
• Easy replacement of battery, even in Ex-area
• Double-sided central locking facility
• Safety interlocking system due to an integrated forced
isolating switch
• Safety standard IP66

There are currently no videos available for this product
Brand
CEAG CROUSE HINDS
Height
1500 mm
Width
188 mm
Depth
130 mm
Weight
12 kg
IP Rating
IP66
Body Material
GRP
Minimum Operating Temperature
-20 °C
Maximum Operating Temperature
50 °C
ATEX Approval - Dust
Ex tb IIIC T80°C Db
ATEX Approval - Gas
Ex de mb ib IIC T4 Gb
Hazadrous Area Certification
1, 2, 21, 22
Approvals
ATEX, IECEx
ATEX Certificate Number
BVS 09 ATEX E 034, IECEx BVS 09.0033
Cable Entry Method
Internal Brass ECP
Emergency Output
1.5 Hours, 3 Hours
Lens Colour
Clear
Number Of Earth Terminals
1
Number Of Terminals
5
Voltage Rating
230 V AC
Colour
Light Grey
Size Reference
1200 mm, 4 Ft
Rated Frequency
50 Hz, 60 Hz
Wiring
Loop In Loop Out, Through Wired
Light Source
Fluorescent
Cable Entries
4 x M20
Nominal Output
2 x 36 W
Maximum Conductor Size
6 mm²
Additional Features
Emergency Mode: Maintained or Non-Maintained