Contact Us Mon-Fri 7am to 6pm, Sat 8:30am to 12pm
ex. VAT inc. VAT Register Sign In
FAZ-B1/2
FAZ-B1/2

15KA DP MCB 1AMP TYPE B

My Part Number:

Part Number: FAZ-B1/2

Manufacturer Code: 278719

Multiples of: 1 | Minimum Order: 1

View Technical Documents
Currently out of stock - available to back order

Eaton Moeller series xEffect - FAZ MCB. FAZ, 2-pole, tripping characteristic: B, rated current In: 1 A


Product length/depth: 80 mm
Product height: 75.5 mm
Product width: 36 mm
Application: Branch circuits, not as BCPD, Switchgear for industrial and advanced commercial applications, xEffect - Switchgear for industrial and advanced commercial applications
Number of poles: Two-pole
Number of poles (total): 2
Number of poles (protected): 2
Tripping characteristic: B
Release characteristic: B
Amperage rating: 1 A
Type: FAZ, Miniature circuit breaker
Voltage type: AC
Voltage rating: 240 V AC / 415 V AC
Voltage rating (IEC/EN 60898-1): 415 VAC
Voltage rating (UL): 480Y/277 V
Voltage rating (UL CSA 13): 480 Y/277 V AC; 96 V DC
Rated operational voltage (UE) - MAX: 400 V
Operational voltage (IEC/EN 60947-2) - MAX: 440 VAC
Rated insulation voltage (UI): 440 V
Rated impulse withstand voltage (UIMP): 4 kV
Frequency rating - MIN: 50 Hz
Frequency rating - MAX: 60 Hz
Rated switching capacity (IEC/EN 60947-2) At max voltage rating: 10 kA
Rated switching capacity (IEC/EN 60947-2): 15 kA
Rated switching capacity (IEC/EN 60898-1): 10 kA
Breaking capacity: 10 kA (UL1077)
Rated service short-circuit breaking capacity (IEC/EN 60898-1): 7.5 kA
Rated service short-circuit breaking capacity (IEC/EN 60947-2): 7.5 kA
Rated short-circuit breaking capacity (EN 60898) AT 230 V: 10 kA
Rated short-circuit breaking capacity (EN 60898) AT 400 V: 10 kA
Rated short-circuit breaking capacity (IEC 60947-2) AT 230 V: 15 kA
Rated short-circuit breaking capacity (IEC 60947-2) AT 400 V: 15 kA
Overvoltage category: III
Pollution degree: 2
Width in number of modular spacings: 2
Built-in depth: 70.5 mm
Degree of protection: UL/CSA Type: - IP20 (IEC), IP20
Connectable conductor cross section (SOLID-CORE) - MIN: 1 mm²
Connectable conductor cross section (SOLID-CORE) - MAX: 25 mm²
Connectable conductor cross section (MULTI-WIRED) - MIN: 1 mm²
Connectable conductor cross section (MULTI-WIRED) - MAX: 25 mm²

There are currently no videos available for this product
Brand
EATON MOELLER ELECTRIC
Current Rating
1 A
Number Of Poles
DP
Tripping Curve
Type B

£77.81

per 1 (ex. VAT)

£93.37

per 1 (inc. VAT)
Quantity:

Eaton Moeller series xEffect - FAZ MCB. FAZ, 2-pole, tripping characteristic: B, rated current In: 1 A


Product length/depth: 80 mm
Product height: 75.5 mm
Product width: 36 mm
Application: Branch circuits, not as BCPD, Switchgear for industrial and advanced commercial applications, xEffect - Switchgear for industrial and advanced commercial applications
Number of poles: Two-pole
Number of poles (total): 2
Number of poles (protected): 2
Tripping characteristic: B
Release characteristic: B
Amperage rating: 1 A
Type: FAZ, Miniature circuit breaker
Voltage type: AC
Voltage rating: 240 V AC / 415 V AC
Voltage rating (IEC/EN 60898-1): 415 VAC
Voltage rating (UL): 480Y/277 V
Voltage rating (UL CSA 13): 480 Y/277 V AC; 96 V DC
Rated operational voltage (UE) - MAX: 400 V
Operational voltage (IEC/EN 60947-2) - MAX: 440 VAC
Rated insulation voltage (UI): 440 V
Rated impulse withstand voltage (UIMP): 4 kV
Frequency rating - MIN: 50 Hz
Frequency rating - MAX: 60 Hz
Rated switching capacity (IEC/EN 60947-2) At max voltage rating: 10 kA
Rated switching capacity (IEC/EN 60947-2): 15 kA
Rated switching capacity (IEC/EN 60898-1): 10 kA
Breaking capacity: 10 kA (UL1077)
Rated service short-circuit breaking capacity (IEC/EN 60898-1): 7.5 kA
Rated service short-circuit breaking capacity (IEC/EN 60947-2): 7.5 kA
Rated short-circuit breaking capacity (EN 60898) AT 230 V: 10 kA
Rated short-circuit breaking capacity (EN 60898) AT 400 V: 10 kA
Rated short-circuit breaking capacity (IEC 60947-2) AT 230 V: 15 kA
Rated short-circuit breaking capacity (IEC 60947-2) AT 400 V: 15 kA
Overvoltage category: III
Pollution degree: 2
Width in number of modular spacings: 2
Built-in depth: 70.5 mm
Degree of protection: UL/CSA Type: - IP20 (IEC), IP20
Connectable conductor cross section (SOLID-CORE) - MIN: 1 mm²
Connectable conductor cross section (SOLID-CORE) - MAX: 25 mm²
Connectable conductor cross section (MULTI-WIRED) - MIN: 1 mm²
Connectable conductor cross section (MULTI-WIRED) - MAX: 25 mm²

There are currently no videos available for this product
Brand
EATON MOELLER ELECTRIC
Current Rating
1 A
Number Of Poles
DP
Tripping Curve
Type B