My Part Number:
Part Number: LS-XG-ZBZ
Manufacturer Code: 106833
Multiples of: 1 | Minimum Order: 1
Eaton Moeller® series LS Actuator, flat
Type: Actuator, Flat actuator
Operating Frequency: 800 Operations/h
Pollution Degree: 3
Climatic Proofing: Damp heat, cyclic, to IEC 60068-2-30, Damp heat, constant, to IEC 60068-2-78
Rated Impulse Withstand Voltage (UIMP): 4000 V AC
Ambient Operating Temperature - Max: 40 °C
Ambient Operating Temperature - Min: -25 °C
Equipment Heat Dissipation, Current-Dependent PVID: 0 W
Heat Dissipation Capacity PDISS: 0 W
Heat Dissipation Per Pole, Current-Dependent PVID: 0 W
Rated Insulation Voltage (UI): 400 V
Rated Operational Current For Specified Heat Dissipation (IN): 0 A
Static Heat Dissipation, Non-Current-Dependent PVS: 0 W
Functions: For combination with LS-...ZBZ/X basic devices
Mounting Position: As required
Material: Stainless steel
Overvoltage Category: III
Duty Factor: 100 %
Voltage Tolerance: 1.1 x Us, Pick-up and drop-out values, 0.85 x Us, Pick-up and drop-out values
Repetition Accuracy: 0.02 mm (Contacts/switching capacity)
Shock Resistance: 10 g, Standard-action contact, Mechanical, Half-Sinusoidal shock 20 ms
Mechanical Holding Force: 1600 N (according to GS-ET-19 (04/2004), XWA, XFG, XF), 1700 N (according to GS-ET-19 (04/2004), XG, XW, XNG), 1200 N (according to GS-ET-19 (04/2004), XNW)
Supply Frequency: Max. 400 Hz, Contacts
Model: Standard actuator
Power Consumption: 8 W at 24 V DC (electromechanical actuation), 8 VA at 120 V AC (electromechanical actuation)
Rated Operational Current (IE): 0.8 A at 110 V, 4 A at AC-15, 380 V 400 V 415 V, 3 A at 24 V, 0.3 A at 220 V, 6 A at AC-15, 220 V 230 V 240 V, 6 A at AC-15, 24 V
Short-Circuit Protection Rating: Max. 6 A gG/gL, Fuse, Contacts
Terminal Capacity (Flexible With Ferrule): 2 x (0.5 - 1.5) mm², 1 x (0.5 - 1.5) mm²
Terminal Capacity (Solid): 2 x (0.75 - 1.5) mm², 1 x (0.75 - 2.5) mm²
Brand |
EATON MOELLER ELECTRIC |
|
£7.96
per 1 (ex. VAT)£9.55
per 1 (inc. VAT)
Eaton Moeller® series LS Actuator, flat
Type: Actuator, Flat actuator
Operating Frequency: 800 Operations/h
Pollution Degree: 3
Climatic Proofing: Damp heat, cyclic, to IEC 60068-2-30, Damp heat, constant, to IEC 60068-2-78
Rated Impulse Withstand Voltage (UIMP): 4000 V AC
Ambient Operating Temperature - Max: 40 °C
Ambient Operating Temperature - Min: -25 °C
Equipment Heat Dissipation, Current-Dependent PVID: 0 W
Heat Dissipation Capacity PDISS: 0 W
Heat Dissipation Per Pole, Current-Dependent PVID: 0 W
Rated Insulation Voltage (UI): 400 V
Rated Operational Current For Specified Heat Dissipation (IN): 0 A
Static Heat Dissipation, Non-Current-Dependent PVS: 0 W
Functions: For combination with LS-...ZBZ/X basic devices
Mounting Position: As required
Material: Stainless steel
Overvoltage Category: III
Duty Factor: 100 %
Voltage Tolerance: 1.1 x Us, Pick-up and drop-out values, 0.85 x Us, Pick-up and drop-out values
Repetition Accuracy: 0.02 mm (Contacts/switching capacity)
Shock Resistance: 10 g, Standard-action contact, Mechanical, Half-Sinusoidal shock 20 ms
Mechanical Holding Force: 1600 N (according to GS-ET-19 (04/2004), XWA, XFG, XF), 1700 N (according to GS-ET-19 (04/2004), XG, XW, XNG), 1200 N (according to GS-ET-19 (04/2004), XNW)
Supply Frequency: Max. 400 Hz, Contacts
Model: Standard actuator
Power Consumption: 8 W at 24 V DC (electromechanical actuation), 8 VA at 120 V AC (electromechanical actuation)
Rated Operational Current (IE): 0.8 A at 110 V, 4 A at AC-15, 380 V 400 V 415 V, 3 A at 24 V, 0.3 A at 220 V, 6 A at AC-15, 220 V 230 V 240 V, 6 A at AC-15, 24 V
Short-Circuit Protection Rating: Max. 6 A gG/gL, Fuse, Contacts
Terminal Capacity (Flexible With Ferrule): 2 x (0.5 - 1.5) mm², 1 x (0.5 - 1.5) mm²
Terminal Capacity (Solid): 2 x (0.75 - 1.5) mm², 1 x (0.75 - 2.5) mm²
Brand |