MIM ELECTROMAGNETIC FLOW METER 0.4-100L/MIN. G1" MALE, TFT DISPLAY, M12, 24V DC. OUTPUTS 4-20MA, NPN/PNP/PP, PT1000

My Part Number:

Part Number: MIM-12-20H-G6-C3T-0

Multiples of: 1 | Minimum Order: 1

View Technical Documents
In Stock - available to order online

Magnetic Inductive Flow Meter - All Metal - Stainless Steel - MIM


The MIM is completely made in stainless steel. In addition to the temperature measurement function, the MIM can be used for very small nominal pipe sizes and covers an even larger measuring range, depending on the nominal size - from 30 ml /min upwards. "The flow meters have two individually configurable outputs that can act as a pulse, alarm or analogue output, depending on the setting," explains Raza Ali Agha. "This makes them easier to integrate into different processes or auxiliary circuits." The colour multi-display can also rotate digitally in 90 ° increments, so that when changing location, no other model is required, and the display is independent of the position of the connections.

The response time has now been improved to facilitate more precise dosing quantities. In addition, different subsets can be programmed via the menu in order not to have to navigate awkwardly with each new setting through the menu. The display has also been extended to so-called hotkeys. With this feature, the desired dosage can be conveniently selected by optical buttons on the home screen. The desired dosing process can be started and stopped via an external control input, and, the quantity can also be changed via MIM at any time. "Precisely measured quantities and a very good response time are indispensable, especially for sensitive processes such as tablet coating," confirms Raza Ali Agha.

To ensure that this possibility is also available for hot media and in extremely temperature-controlled environments such as cooling water circuits, KOBOLD is offering for the first time a device in remote version. Unlike conventional devices, the media-contacting unit only contains the sensor. The entire electronics, the control and display, are housed separately and connected via a cable at a safe distance to the sensor unit on the pipe. As a result, even temperatures from -40°C up to +140 ° C are not problem and the flow meter can work trouble-free because the electronics remain protected.


Options/Features:
integrated PT1000, dosing function, rotatable TFT display, bidirectional measurement, part- and grand totalizer, stainless steel design, usable even with hand gloves

Brand
KOBOLD INSTRUMENTS
Display Type
TFT
Electrical Connection
M12 x 1
IP Rating
IP67
Body Material
316L Stainless Steel
Number Of Pins
4
Supply Voltage
24 V DC
Communication Protocol
IO Link
Acceptable Media
Conductive Liquid
Wetted Parts
316L Stainless Steel, Peek
Seal Material
FKM
Measuring Principle
Electromagnetic
Process Connection
G1" Male
Minimum Sensing Range
0.4 L/min
Maximum Sensing Range
100 L/min
Output Signal
1 x 4-20 mA/0-10 V/PP, 1 x NPN/PNP/PP
Maximum Ambient Temperature
60 °C
Maximum Pressure
16 bar
Maximum Media Temperature
70 °C

£766.00

per 1 (ex. VAT)

£919.20

per 1 (inc. VAT)
Quantity:

Magnetic Inductive Flow Meter - All Metal - Stainless Steel - MIM


The MIM is completely made in stainless steel. In addition to the temperature measurement function, the MIM can be used for very small nominal pipe sizes and covers an even larger measuring range, depending on the nominal size - from 30 ml /min upwards. "The flow meters have two individually configurable outputs that can act as a pulse, alarm or analogue output, depending on the setting," explains Raza Ali Agha. "This makes them easier to integrate into different processes or auxiliary circuits." The colour multi-display can also rotate digitally in 90 ° increments, so that when changing location, no other model is required, and the display is independent of the position of the connections.

The response time has now been improved to facilitate more precise dosing quantities. In addition, different subsets can be programmed via the menu in order not to have to navigate awkwardly with each new setting through the menu. The display has also been extended to so-called hotkeys. With this feature, the desired dosage can be conveniently selected by optical buttons on the home screen. The desired dosing process can be started and stopped via an external control input, and, the quantity can also be changed via MIM at any time. "Precisely measured quantities and a very good response time are indispensable, especially for sensitive processes such as tablet coating," confirms Raza Ali Agha.

To ensure that this possibility is also available for hot media and in extremely temperature-controlled environments such as cooling water circuits, KOBOLD is offering for the first time a device in remote version. Unlike conventional devices, the media-contacting unit only contains the sensor. The entire electronics, the control and display, are housed separately and connected via a cable at a safe distance to the sensor unit on the pipe. As a result, even temperatures from -40°C up to +140 ° C are not problem and the flow meter can work trouble-free because the electronics remain protected.


Options/Features:
integrated PT1000, dosing function, rotatable TFT display, bidirectional measurement, part- and grand totalizer, stainless steel design, usable even with hand gloves

Brand
KOBOLD INSTRUMENTS
Display Type
TFT
Electrical Connection
M12 x 1
IP Rating
IP67
Body Material
316L Stainless Steel
Number Of Pins
4
Supply Voltage
24 V DC
Communication Protocol
IO Link
Acceptable Media
Conductive Liquid
Wetted Parts
316L Stainless Steel, Peek
Seal Material
FKM
Measuring Principle
Electromagnetic
Process Connection
G1" Male
Minimum Sensing Range
0.4 L/min
Maximum Sensing Range
100 L/min
Output Signal
1 x 4-20 mA/0-10 V/PP, 1 x NPN/PNP/PP
Maximum Ambient Temperature
60 °C
Maximum Pressure
16 bar
Maximum Media Temperature
70 °C