Contact Us Mon-Fri 7am to 6pm, Sat 8:30am to 12pm
ex. VAT inc. VAT Register Sign In
16973
16973

2POLE SI RCB RATED 125A 300MA

My Part Number:

Part Number: 16973

Multiples of: 1 | Minimum Order: 1

View Technical Documents
In Stock - available to order online

Residual current circuit breaker ID si - 2 poles - 125 A - class A 300 mA

Range: Acti 9
Product or component type: Residual current circuit breaker (RCCB)
Poles description: 2P
Neutral position: Left
[In] rated current: 125 A
Network type: AC
Earth-leakage sensitivity: 300 mA
Earth-leakage protection time delay: Instantaneous
Earth-leakage protection class: Type A-SI
Rated breaking and making capacity: Im = 1250 A 230 V conforming to IEC 61008
Rated conditional short-circuit current: Inc 10 kA 125 A
Device location in system: Outgoer
Network frequency: 50/60 Hz
[Ue] rated operational voltage: 230 V AC 50 Hz conforming to IEC 61008
Residual current tripping technology: Electromechanical
[Ui] rated insulation voltage: 440 V AC 50 Hz conforming to IEC 61008-1
[Uimp] rated impulse withstand voltage: 4 kV conforming to IEC 61008-1
Control type: Toggle
Mounting mode: Fixed
Mounting support: 35 mm symmetrical DIN rail
9 mm pitches: 4
Height: 86 mm
Width: 36 mm
Depth: 76 mm
Colour: Grey
Mechanical durability: 5000 cycles
Electrical durability: 2000 cycles
Provision for padlocking: Padlockable

There are currently no videos available for this product
Brand
SCHNEIDER MERLIN GERIN

£324.00

per 1 (ex. VAT)

£388.80

per 1 (inc. VAT)
Quantity:

Residual current circuit breaker ID si - 2 poles - 125 A - class A 300 mA

Range: Acti 9
Product or component type: Residual current circuit breaker (RCCB)
Poles description: 2P
Neutral position: Left
[In] rated current: 125 A
Network type: AC
Earth-leakage sensitivity: 300 mA
Earth-leakage protection time delay: Instantaneous
Earth-leakage protection class: Type A-SI
Rated breaking and making capacity: Im = 1250 A 230 V conforming to IEC 61008
Rated conditional short-circuit current: Inc 10 kA 125 A
Device location in system: Outgoer
Network frequency: 50/60 Hz
[Ue] rated operational voltage: 230 V AC 50 Hz conforming to IEC 61008
Residual current tripping technology: Electromechanical
[Ui] rated insulation voltage: 440 V AC 50 Hz conforming to IEC 61008-1
[Uimp] rated impulse withstand voltage: 4 kV conforming to IEC 61008-1
Control type: Toggle
Mounting mode: Fixed
Mounting support: 35 mm symmetrical DIN rail
9 mm pitches: 4
Height: 86 mm
Width: 36 mm
Depth: 76 mm
Colour: Grey
Mechanical durability: 5000 cycles
Electrical durability: 2000 cycles
Provision for padlocking: Padlockable

There are currently no videos available for this product
Brand
SCHNEIDER MERLIN GERIN