Contact Us Mon-Fri 7am to 6pm, Sat 8:30am to 12pm
ex. VAT inc. VAT Register Sign In
2905028
2905028
2905028
2905028
2905028
2905028

MINI MCR-2-UNI-UI-2UI-PT

My Part Number:

Part Number: 2905028

Manufacturer Code: MINI MCR-2-UNI-UI-2UI-PT

Multiples of: 1 | Minimum Order: 1

View Technical Documents
In Stock - available to order online

MINI MCR-2-UNI-UI-2UI-PT - Signal duplicator


Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration.

Configurable, freely adjustable 4-way signal duplicator with plug-in connection technology for the duplication, electrical isolation, conversion, amplification, and filtering of standard signals. Current signals between 0 mA ... 24 mA and voltage signals between 0 V ... 12 V can be processed on the input side. Signals between 0 mA ... 21 mA and 0 V ... 10.5 V are possible on the output side. Both output signals can be set independently of one another.

The minimum measuring span is 1 mA and 0.5 V. Full accuracy is maintained with a measuring span greater than 10 mA and 5 V. You can configure the device using one of the free software solutions. Default settings can also be made directly on the device by simply using the DIP switches (see configuration table). The measuring transducer supports fault monitoring and NFC communication.

Product type: Signal duplicator
Product family: MINI Analog Pro
No. of channels: 2
Type: Signal conditioner
Configuration: DIP switches, Software, App

Insulation characteristics: GB Standard
Overvoltage category: II
Pollution degree: 2

Functionality
Configuration: DIP switches, Software, App

Electrical isolation: 4-way isolation
Step response (0–99%): 140 ms (15 Hz sample rate), 45 ms (60 Hz sample rate), 25 ms (240 Hz sample rate, can only be set via software)
Maximum temperature coefficient: 0.01 %/K
Maximum transmission error: 0.05 % (of final value)

Electrical isolation Input/output/power supply
Rated insulation voltage: 300 Vrms
Test voltage: 3 kV AC (50 Hz, 60 s)
Insulation: Reinforced insulation according to IEC/EN 61010-1

Supply
Nominal supply voltage: 24 V DC
Supply voltage range: 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption: 55 mA (24 V DC), 110 mA (12 V DC)
Power consumption: 1.5 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)

Connection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm² (with ferrule), 0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12 (flexible)

There are currently no videos available for this product
Brand
PHOENIX CONTACT

£274.57

per 1 (ex. VAT)

£329.48

per 1 (inc. VAT)
Quantity:

MINI MCR-2-UNI-UI-2UI-PT - Signal duplicator


Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration.

Configurable, freely adjustable 4-way signal duplicator with plug-in connection technology for the duplication, electrical isolation, conversion, amplification, and filtering of standard signals. Current signals between 0 mA ... 24 mA and voltage signals between 0 V ... 12 V can be processed on the input side. Signals between 0 mA ... 21 mA and 0 V ... 10.5 V are possible on the output side. Both output signals can be set independently of one another.

The minimum measuring span is 1 mA and 0.5 V. Full accuracy is maintained with a measuring span greater than 10 mA and 5 V. You can configure the device using one of the free software solutions. Default settings can also be made directly on the device by simply using the DIP switches (see configuration table). The measuring transducer supports fault monitoring and NFC communication.

Product type: Signal duplicator
Product family: MINI Analog Pro
No. of channels: 2
Type: Signal conditioner
Configuration: DIP switches, Software, App

Insulation characteristics: GB Standard
Overvoltage category: II
Pollution degree: 2

Functionality
Configuration: DIP switches, Software, App

Electrical isolation: 4-way isolation
Step response (0–99%): 140 ms (15 Hz sample rate), 45 ms (60 Hz sample rate), 25 ms (240 Hz sample rate, can only be set via software)
Maximum temperature coefficient: 0.01 %/K
Maximum transmission error: 0.05 % (of final value)

Electrical isolation Input/output/power supply
Rated insulation voltage: 300 Vrms
Test voltage: 3 kV AC (50 Hz, 60 s)
Insulation: Reinforced insulation according to IEC/EN 61010-1

Supply
Nominal supply voltage: 24 V DC
Supply voltage range: 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption: 55 mA (24 V DC), 110 mA (12 V DC)
Power consumption: 1.5 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)

Connection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm² (with ferrule), 0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12 (flexible)

There are currently no videos available for this product
Brand
PHOENIX CONTACT