Part Number: Z-KEY-2ETH-E
Multiples of: 1 | Minimum Order: 1
2-port EtherNet/IP -> ModBUS RTU/ASCII/TCP-IP gateway & protocol converter, dual Ethernet
SENECA offers three Ethernet/IP gateway variants that differ in form factor and number of Ethernet ports. The Z-KEY-2ETH Ethernet/IP model is designed to simplify network communications between Modbus RTU/ASCII/TCP devices and EtherNet/IP networks. This gateway takes on the main function of acting as a Modbus master to acquire and exchange data with EtherNet/IP devices.
Concretely, the R-KEY-LT converts Modbus data into EtherNet/IP packets, enabling an EtherNet/IP scanner to control or monitor Modbus devices. In detail, the Ethernet/IP gateway works as ModBUS Master devices on the serial side and Ethernet/IP adapters on the Ethernet side. Modbus requests, such as read or write commands, are configured directly on the devices, automatically generating an EDS file. Once this file is imported into the PLC development software, all configured I/O will be accessible without further configuration. In addition, up to 3 Modbus TCP-IP servers can be connected in addition to the serial devices.
Power supply: 10..40 Vdc; 19..28 Vac
Absorption: Max 2 W
LED status indicators: Power supply, Rx/Tx RS232/RS485 port, Rx/Tx RS485 port, Transmission/Ethernet connection, Ethernet/IP communication
Isolation 1.5 kVac (4-way): Grade of protection IP20
Operating temperature: -25..+65°C
Connections: 3-way removable screw terminals, 5 mm pitch, Rear IDC10 connector for DIN rail 46277, 2x Front RJ45 connector
Ethernet ports: No.2 Fast Ethernet ports 100 Tx, RJ45 front
Serial ports: Nr.1 RS232 / RS485 switchable port, max 115k baud rate on connector, Nr.1 RS485 port, max 115k baud rate on IDC10 connector for bus and terminals
Supported protocols: ModBUS RTU, ModBUS TCP-IP, ModBUS ASCII
Operating mode: ModBUS RTU/TCP-IP/ASCII -> Ethernet/IP Gateway
Dedicated memory area for commands: 512 Bytes READ and 512 Bytes WRITE
Max client TCP-IP (SERVER MODE): 3
Max modbus RTU/ASCII slave nodes: 128
Dimension (WXHXD): 17.5 x 100 x 112 mm
Weight: 100 g
Case: Nylon 6 com 30% glass fiber, self-extinguishing class V0
Installation: For DIN rail (IEC EN 60715)
Certifications: CE, UKCA
DIP switch: Flash memory, IP address, serial activation
Web server: Ethernet/IP parameters, ModBUS registers, firmware update, serial traffic, I/O mapping, EDS export
Configuration file: EDS
SDD (SENECA DISCOVERY DEVICE): x
Brand |
SENECA |
|
£191.82
per 1 (ex. VAT)£230.18
per 1 (inc. VAT)
2-port EtherNet/IP -> ModBUS RTU/ASCII/TCP-IP gateway & protocol converter, dual Ethernet
SENECA offers three Ethernet/IP gateway variants that differ in form factor and number of Ethernet ports. The Z-KEY-2ETH Ethernet/IP model is designed to simplify network communications between Modbus RTU/ASCII/TCP devices and EtherNet/IP networks. This gateway takes on the main function of acting as a Modbus master to acquire and exchange data with EtherNet/IP devices.
Concretely, the R-KEY-LT converts Modbus data into EtherNet/IP packets, enabling an EtherNet/IP scanner to control or monitor Modbus devices. In detail, the Ethernet/IP gateway works as ModBUS Master devices on the serial side and Ethernet/IP adapters on the Ethernet side. Modbus requests, such as read or write commands, are configured directly on the devices, automatically generating an EDS file. Once this file is imported into the PLC development software, all configured I/O will be accessible without further configuration. In addition, up to 3 Modbus TCP-IP servers can be connected in addition to the serial devices.
Power supply: 10..40 Vdc; 19..28 Vac
Absorption: Max 2 W
LED status indicators: Power supply, Rx/Tx RS232/RS485 port, Rx/Tx RS485 port, Transmission/Ethernet connection, Ethernet/IP communication
Isolation 1.5 kVac (4-way): Grade of protection IP20
Operating temperature: -25..+65°C
Connections: 3-way removable screw terminals, 5 mm pitch, Rear IDC10 connector for DIN rail 46277, 2x Front RJ45 connector
Ethernet ports: No.2 Fast Ethernet ports 100 Tx, RJ45 front
Serial ports: Nr.1 RS232 / RS485 switchable port, max 115k baud rate on connector, Nr.1 RS485 port, max 115k baud rate on IDC10 connector for bus and terminals
Supported protocols: ModBUS RTU, ModBUS TCP-IP, ModBUS ASCII
Operating mode: ModBUS RTU/TCP-IP/ASCII -> Ethernet/IP Gateway
Dedicated memory area for commands: 512 Bytes READ and 512 Bytes WRITE
Max client TCP-IP (SERVER MODE): 3
Max modbus RTU/ASCII slave nodes: 128
Dimension (WXHXD): 17.5 x 100 x 112 mm
Weight: 100 g
Case: Nylon 6 com 30% glass fiber, self-extinguishing class V0
Installation: For DIN rail (IEC EN 60715)
Certifications: CE, UKCA
DIP switch: Flash memory, IP address, serial activation
Web server: Ethernet/IP parameters, ModBUS registers, firmware update, serial traffic, I/O mapping, EDS export
Configuration file: EDS
SDD (SENECA DISCOVERY DEVICE): x