My Part Number:
Part Number: FTS-I060F14B
Manufacturer Code: 1114232
Multiples of: 1 | Minimum Order: 1
Measurement principle: Calorimetric measurement process
Medium: Water and oil-based liquids
Pipe diameters: ≥ 25 mm 1)
Measuring range: 3 cm/s ... 300 cm/s, Water, 3 cm/s ... 300 cm/s, Oil A / Oil B, 3 cm/s ... 600 cm/s, Taught-in media 2)
Process temperature: –40 °C ... +150 °C 3)
Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (with SICK T-connector DN50) 4)
Communication interface: IO-Link, IO-Link V1.1, COM3 (230.4 kbit/s)
Temperature measurement: ✔
Display: ✔, OLED + 3 status LEDs
1) Place probe tip in the center of the pipe to ensure the highest measurement accuracy.
2) The measuring range limit value depends on the medium used.
3) At medium temperatures above 100 °C, the distance between the bottom of the housing and the top of the process connection adapter must be at least 25 mm. If a SICK process connection adapter is used, the 60 mm probe cannot be used at process temperatures above 100 °C because the distances cannot be maintained.
4) According to the Pressure Equipment Directive 2014/68 / EU: Good engineering practice, according to Article 13 for media of media group 2 (other substances).
Brand |
SICK |
|
£348.13
per 1 (ex. VAT)£417.76
per 1 (inc. VAT)
Measurement principle: Calorimetric measurement process
Medium: Water and oil-based liquids
Pipe diameters: ≥ 25 mm 1)
Measuring range: 3 cm/s ... 300 cm/s, Water, 3 cm/s ... 300 cm/s, Oil A / Oil B, 3 cm/s ... 600 cm/s, Taught-in media 2)
Process temperature: –40 °C ... +150 °C 3)
Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (with SICK T-connector DN50) 4)
Communication interface: IO-Link, IO-Link V1.1, COM3 (230.4 kbit/s)
Temperature measurement: ✔
Display: ✔, OLED + 3 status LEDs
1) Place probe tip in the center of the pipe to ensure the highest measurement accuracy.
2) The measuring range limit value depends on the medium used.
3) At medium temperatures above 100 °C, the distance between the bottom of the housing and the top of the process connection adapter must be at least 25 mm. If a SICK process connection adapter is used, the 60 mm probe cannot be used at process temperatures above 100 °C because the distances cannot be maintained.
4) According to the Pressure Equipment Directive 2014/68 / EU: Good engineering practice, according to Article 13 for media of media group 2 (other substances).
Brand |
SICK |
|