My Part Number:
Part Number: OD2-P250W150I0
Manufacturer Code: 6036645
Multiples of: 1 | Minimum Order: 1
Laser distance sensors: OD Value - OD2-P250W150I0
Measuring range: 100 mm ... 400 mm
Target: Natural objects
Repeatability: 75 µm
Linearity: ± 750 µm
Response time: ≥ 1 ms
Output time: ≥ 0.75 ms
Light source: Laser, red, visible red light
Type of light: Visible red light
Laser class: 2 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm)
Additional function: Mean-value setting 1 … 64x, Automatic sensitivity adjustment, Analog outputs can be taught in, Invertable analog output, Teach-in of digital output, Invertable switching output, Multifunctional input: laser-off / external teach-in / trigger, Switching mode: distance to object (DtO), Switching mode: window (Wnd)
Safety-related parameters:
MTTFD: 101 years
DCavg: 0%
Brand |
SICK |
|
£934.65
per 1 (ex. VAT)£1,121.58
per 1 (inc. VAT)
Laser distance sensors: OD Value - OD2-P250W150I0
Measuring range: 100 mm ... 400 mm
Target: Natural objects
Repeatability: 75 µm
Linearity: ± 750 µm
Response time: ≥ 1 ms
Output time: ≥ 0.75 ms
Light source: Laser, red, visible red light
Type of light: Visible red light
Laser class: 2 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm)
Additional function: Mean-value setting 1 … 64x, Automatic sensitivity adjustment, Analog outputs can be taught in, Invertable analog output, Teach-in of digital output, Invertable switching output, Multifunctional input: laser-off / external teach-in / trigger, Switching mode: distance to object (DtO), Switching mode: window (Wnd)
Safety-related parameters:
MTTFD: 101 years
DCavg: 0%
Brand |
SICK |
|