My Part Number:
Part Number: LADR0
Multiples of: 1 | Minimum Order: 1
TeSys D - time delay auxiliary contact block - 1 NO + 1 NC screw clamp terminals
Range of product: TeSys D control relay, TeSys F, TeSys D
Product or component type: Time delay auxiliary contact block
Pole contact composition: 1 NO + 1 NC
Mounting location: Front
[Ui] rated insulation voltage: 600 V - certifications UL, 690 V conforming to IEC 60947-5-1, 600 V - certifications CSA
[Ue] rated operational voltage: 690 V AC 25-400 Hz
[Ith] conventional free air thermal current: 10 A (at 60 °C)
Irms rated making capacity: 140 A AC conforming to IEC 60947-5-1, 250 A DC conforming to IEC 60947-5-1, 120 A 60 °C 500 ms, 140 A 60 °C 100 ms
Protection type: GG fuse 10 A rating according to operational current for Ue <= 690 V
Associated fuse rating: 10 A gG conforming to IEC 60947-5-1
Mechanical durability: 5 Mcycles
Minimum switching current: 5 mA
Minimum switching voltage: 17 V
Non-overlap time: 1.5 ms on de-energisation no overlap between NC and NO contact, 1.5 ms on energisation no overlap between NC and NO contact
Timer type: Off delay
Time delay range: 0.1-3 s
Insulation resistance: > 10 MOhm
Brand |
SCHNEIDER TELEMECANIQUE |
|
£93.08
per 1 (ex. VAT)£111.70
per 1 (inc. VAT)
TeSys D - time delay auxiliary contact block - 1 NO + 1 NC screw clamp terminals
Range of product: TeSys D control relay, TeSys F, TeSys D
Product or component type: Time delay auxiliary contact block
Pole contact composition: 1 NO + 1 NC
Mounting location: Front
[Ui] rated insulation voltage: 600 V - certifications UL, 690 V conforming to IEC 60947-5-1, 600 V - certifications CSA
[Ue] rated operational voltage: 690 V AC 25-400 Hz
[Ith] conventional free air thermal current: 10 A (at 60 °C)
Irms rated making capacity: 140 A AC conforming to IEC 60947-5-1, 250 A DC conforming to IEC 60947-5-1, 120 A 60 °C 500 ms, 140 A 60 °C 100 ms
Protection type: GG fuse 10 A rating according to operational current for Ue <= 690 V
Associated fuse rating: 10 A gG conforming to IEC 60947-5-1
Mechanical durability: 5 Mcycles
Minimum switching current: 5 mA
Minimum switching voltage: 17 V
Non-overlap time: 1.5 ms on de-energisation no overlap between NC and NO contact, 1.5 ms on energisation no overlap between NC and NO contact
Timer type: Off delay
Time delay range: 0.1-3 s
Insulation resistance: > 10 MOhm
Brand |
SCHNEIDER TELEMECANIQUE |
|