My Part Number:
Part Number: LC1D09E7
Multiples of: 1 | Minimum Order: 1
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 48 V AC coil
Range: TeSys
Product or component type: Contactor
Contactor application: Motor control, Resistive load
Utilisation category: AC-3, AC-4, AC-1
Poles description: 3P
Power pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz, Power circuit: <= 300 V DC
[Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 48 V AC 50/60 Hz
Auxiliary contact composition: 1 NO + 1 NC
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
Overvoltage category: III
[Ith] conventional free air thermal current: 25 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947
Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Electrical durability: 0.6 Mcycles 25 A AC-1 at Ue <= 440 V, 2 Mcycles 9 A AC-3 at Ue <= 440 V
Power dissipation per pole: 1.56 W AC-1, 0.2 W AC-3
Safety cover: With
Mounting support: Rail, Plate
Brand |
SCHNEIDER TELEMECANIQUE |
|
Coil Voltage |
48 V AC |
|
kW Rating |
4 kW |
|
Number Of Poles |
3 Pole |
|
£45.32
per 1 (ex. VAT)£54.38
per 1 (inc. VAT)
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 48 V AC coil
Range: TeSys
Product or component type: Contactor
Contactor application: Motor control, Resistive load
Utilisation category: AC-3, AC-4, AC-1
Poles description: 3P
Power pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz, Power circuit: <= 300 V DC
[Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 48 V AC 50/60 Hz
Auxiliary contact composition: 1 NO + 1 NC
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
Overvoltage category: III
[Ith] conventional free air thermal current: 25 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947
Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Electrical durability: 0.6 Mcycles 25 A AC-1 at Ue <= 440 V, 2 Mcycles 9 A AC-3 at Ue <= 440 V
Power dissipation per pole: 1.56 W AC-1, 0.2 W AC-3
Safety cover: With
Mounting support: Rail, Plate
Brand |
SCHNEIDER TELEMECANIQUE |
|
Coil Voltage |
48 V AC |
|
kW Rating |
4 kW |
|
Number Of Poles |
3 Pole |
|