My Part Number:
Part Number: LUCC18BL
Multiples of: 1 | Minimum Order: 1
Advanced control unit, TeSys U, 4.5-18A, 1P motors, protection & diagnostic, class 10, coil 24V DC
Range of product: TeSys U
Product or component type: Advanced control unit
Device application: Motor control, Motor protection
Product specific application: Basic protection and advanced functions, communication
Main function available: Protection against overload and short-circuit, Manual reset, Earth fault protection, Protection against phase failure and phase imbalance
Product compatibility: Power base LUB32, Power base LUB38, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL
[Ue] rated operational voltage: 690 V AC
Network frequency: 40-60 Hz
Load type: Single-phase motor
Utilisation category: AC-41, AC-43, AC-44
Motor power: kW 4 kW at 400-440 V AC 50/60 Hz for 1 phase motors
Rated motor current adjustment range: 4.5-18 A
Thermal overload class: Class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-55 °C conforming to IEC 60947-6-2, Class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-55 °C conforming to UL 508
Tripping threshold: 14.2 x Ir +/- 20 %
[Uc] control circuit voltage: 24 V DC
Control circuit voltage limits: 20-27 V for DC circuit 24 V in operation, 14.5 V for DC circuit 24 V drop-out
Typical current consumption: 220 mA at 24 V AC I maximum while closing with LUB32, 220 mA at 24 V AC I maximum while closing with LUB38, 90 mA at 24 V AC I rms sealed with LUB32, 90 mA at 24 V AC I rms sealed with LUB38
Heat dissipation: 3 W for control circuit with LUB32, 3 W for control circuit with LUB38
Operating time: 35 ms opening with LUB32 for control circuit, 35 ms opening with LUB38 for control circuit, 70 ms closing with LUB32 for control circuit, 70 ms closing with LUB38 for control circuit
Reset: Manual reset
Standards: EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
Product certifications: CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2, 600 V conforming to UL 60947-4-1, 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage: 6 kV IEC 60947-6-2
Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing mode: Plug-in (front face)
Width: 45 mm
Height: 66 mm
Depth: 60 mm
Brand |
SCHNEIDER TELEMECANIQUE |
|
£131.96
per 1 (ex. VAT)£158.35
per 1 (inc. VAT)
Advanced control unit, TeSys U, 4.5-18A, 1P motors, protection & diagnostic, class 10, coil 24V DC
Range of product: TeSys U
Product or component type: Advanced control unit
Device application: Motor control, Motor protection
Product specific application: Basic protection and advanced functions, communication
Main function available: Protection against overload and short-circuit, Manual reset, Earth fault protection, Protection against phase failure and phase imbalance
Product compatibility: Power base LUB32, Power base LUB38, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL
[Ue] rated operational voltage: 690 V AC
Network frequency: 40-60 Hz
Load type: Single-phase motor
Utilisation category: AC-41, AC-43, AC-44
Motor power: kW 4 kW at 400-440 V AC 50/60 Hz for 1 phase motors
Rated motor current adjustment range: 4.5-18 A
Thermal overload class: Class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-55 °C conforming to IEC 60947-6-2, Class 10 - frequency limit: 40-60 Hz - temperature compensation: -25-55 °C conforming to UL 508
Tripping threshold: 14.2 x Ir +/- 20 %
[Uc] control circuit voltage: 24 V DC
Control circuit voltage limits: 20-27 V for DC circuit 24 V in operation, 14.5 V for DC circuit 24 V drop-out
Typical current consumption: 220 mA at 24 V AC I maximum while closing with LUB32, 220 mA at 24 V AC I maximum while closing with LUB38, 90 mA at 24 V AC I rms sealed with LUB32, 90 mA at 24 V AC I rms sealed with LUB38
Heat dissipation: 3 W for control circuit with LUB32, 3 W for control circuit with LUB38
Operating time: 35 ms opening with LUB32 for control circuit, 35 ms opening with LUB38 for control circuit, 70 ms closing with LUB32 for control circuit, 70 ms closing with LUB38 for control circuit
Reset: Manual reset
Standards: EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
Product certifications: CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2, 600 V conforming to UL 60947-4-1, 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage: 6 kV IEC 60947-6-2
Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing mode: Plug-in (front face)
Width: 45 mm
Height: 66 mm
Depth: 60 mm
Brand |