My Part Number:
Part Number: C201A
Manufacturer Code: 90301011 / ISC-B01-PNS
Multiples of: 1 | Minimum Order: 1
The most advanced control unit for Inxpect safety radars, with the widest range of communication options.
The C201A Type A control unit can monitor up to 6 Inxpect Smart Sensors, and thanks to its Ethernet connection, it can also be configured remotely using the Inxpect Safety Application in total safety.
PROFISAFE FIELDBUS
The Ethernet Fieldbus permits connection between the control unit and the PLC that controls the machine, to exchange complex information, such as real time operator position, allowing rapid integration with ProfiSafe fieldbuses.
DYNAMIC SETTING OF DETECTION FIELDS
With the C201A it is possible to change the detection field dynamically by selecting in real time one of the 32 available configurations. This features is particularly useful in mobile applications, like AGV (Autonomous Guided Vehicles) and MIR (Mobile Industrial Robots) applications.
SECURE ETHERNET CONFIGURATION
Remote configuration and management protected by industry standard cyber-security protocols.
DIGITAL INPUTS
The C201A control unit has two dual-channel inputs, which support the following functions: muting signal, emergency stop signal, restart signal.
SAFETY OUTPUTS
The C201A control unit has two dual-channel safety OSSDs or four auxiliary outputs, which can be configured to signal restart feedback, fault, muting.
MUTING FUNCTION
The system can be configured to temporarily deactivate some sensors when they are not required to detect motion in the area, allowing operators to access parts of the working area.
Brand |
INXPECT |
|
Supply Voltage |
24 V DC |
|
£1,060.00
per 1 (ex. VAT)£1,272.00
per 1 (inc. VAT)
The most advanced control unit for Inxpect safety radars, with the widest range of communication options.
The C201A Type A control unit can monitor up to 6 Inxpect Smart Sensors, and thanks to its Ethernet connection, it can also be configured remotely using the Inxpect Safety Application in total safety.
PROFISAFE FIELDBUS
The Ethernet Fieldbus permits connection between the control unit and the PLC that controls the machine, to exchange complex information, such as real time operator position, allowing rapid integration with ProfiSafe fieldbuses.
DYNAMIC SETTING OF DETECTION FIELDS
With the C201A it is possible to change the detection field dynamically by selecting in real time one of the 32 available configurations. This features is particularly useful in mobile applications, like AGV (Autonomous Guided Vehicles) and MIR (Mobile Industrial Robots) applications.
SECURE ETHERNET CONFIGURATION
Remote configuration and management protected by industry standard cyber-security protocols.
DIGITAL INPUTS
The C201A control unit has two dual-channel inputs, which support the following functions: muting signal, emergency stop signal, restart signal.
SAFETY OUTPUTS
The C201A control unit has two dual-channel safety OSSDs or four auxiliary outputs, which can be configured to signal restart feedback, fault, muting.
MUTING FUNCTION
The system can be configured to temporarily deactivate some sensors when they are not required to detect motion in the area, allowing operators to access parts of the working area.
Brand |
INXPECT |
|
Supply Voltage |
24 V DC |
|