Part Number: 750-661/000-004
Manufacturer Code: 750-661/000-004
Multiples of: 1 | Minimum Order: 1
Fail-safe 4-channel digital input; 24 VDC; PROFIsafe
The PROFIsafe Module (75x-661/000-004) connects to potential-free emergency stop buttons with contacts, safety interlock switches, operating mode switches, safety sensors and semiconductor outputs.
The module features four clock-sensitive inputs (I1 … I4) that are fed via two differently clocked outputs (T1 … T2).
Clock outputs are short-circuit-protected. Inputs are continually monitored for cross circuits and power supply from separate sources. Additional safety-relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK.
This configuration tool can be conveniently integrated into engineering systems supporting TCI (Tool Calling Interface) with CC2 or CC3.
When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible iPar server – depending on settings. The PROFIsafe address can be set using the DIP switch located on the side of the module, or via WAGO-I/O-CHECK.
The module supports both PROFIsafe V2.4 (PROFIBUS, PROFINET) and V2.6 (PROFINET) protocols.
Field and system levels are electrically isolated.
Individual safety modules can be arranged in any combination when configuring the fieldbus node.
Brand |
WAGO |
|
£166.04
per 1 (ex. VAT)£199.25
per 1 (inc. VAT)
Fail-safe 4-channel digital input; 24 VDC; PROFIsafe
The PROFIsafe Module (75x-661/000-004) connects to potential-free emergency stop buttons with contacts, safety interlock switches, operating mode switches, safety sensors and semiconductor outputs.
The module features four clock-sensitive inputs (I1 … I4) that are fed via two differently clocked outputs (T1 … T2).
Clock outputs are short-circuit-protected. Inputs are continually monitored for cross circuits and power supply from separate sources. Additional safety-relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK.
This configuration tool can be conveniently integrated into engineering systems supporting TCI (Tool Calling Interface) with CC2 or CC3.
When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible iPar server – depending on settings. The PROFIsafe address can be set using the DIP switch located on the side of the module, or via WAGO-I/O-CHECK.
The module supports both PROFIsafe V2.4 (PROFIBUS, PROFINET) and V2.6 (PROFINET) protocols.
Field and system levels are electrically isolated.
Individual safety modules can be arranged in any combination when configuring the fieldbus node.