My Part Number:
Part Number: 750-667/000-003
Manufacturer Code: 750-667/000-003
Multiples of: 1 | Minimum Order: 1
Fail-safe 4/4 channel digital input/output - 24 VDC, 2 A, PROFIsafe V2.0 iPar
The 75x-667/000-003 Module is equipped with four power outputs (O1 … O4) and four clock sensitive inputs (I1 … I4). The sensors can be supplied directly with 24 V, or fed by two differently clocked outputs (T1 … T2).
The inputs connect potential-free, emergency-off switches with contacts, safety interlock switches, mode selectors, as well as both safety sensors and semiconductor outputs (e.g., light barriers, PLC outputs). The power outputs switch both DC13 resistive and inductive loads with up to a 2A-rated current without requiring any additional external circuit.
The power outputs operate in both bipolar (high-side/low-side switching) and unipolar (common potential on one side of the load) modes.
The module monitors short circuits, cross circuits and 24 V power supply from separate sources. Both the monitoring and additional safety-relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK.
The configuration tool can be conveniently integrated into engineering systems supporting both CC2 and CC3 tool calling interfaces (TCI).
When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible iPar server – depending on settings. The PROFIsafe address can be set using the DIP switch on the side of the module, or via WAGO-I/O-CHECK.
The module supports both PROFIsafe V1 (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols.
Safety modules can be arranged in any combination when configuring the fieldbus node.
Number of digital inputs: 4
Number of digital outputs: 4
Total number of channels (module): 8
Signal type: Digital, Voltage
Signal type: 24 VDC
Sensor connection: 4 x (Fail-safe input with test pulse)
Input characteristic: clock sensitive
Input characteristic: Type 1 per IEC 61131
Input current per channel for signal (1) typ.: 2.2mA
Output circuit design: Power outputs
Output current per channel: 2A
Output current (module): 8A
Output current: short-circuit-protected
Switching frequency (max.): 50 Hz; Resistive load
Switching frequency (max.) (2): 0.1 Hz; Inductive load
Capacitive load for each channel: O1 … O4; 2.2 µF
Signal frequency (max.): 50Hz
Configuration options: PROFIsafe address adjustable via DIP switch or engineering software
Supply voltage (system): 5 VDC; via data contacts
Current consumption (5 V system supply): 180mA
Supply voltage (field): 24 VSELV/PELV DC (-15 … +20 %); via power jumper contacts (power supply via blade contact; transmission via spring contact)
Current consumption, field supply (module with no external load): 20mA
Isolation: 500 V system/field
Indicators: LED (A-D) green/red: Status/Error I1 … I4; LED (I-M) green/red: Status/error O1 … O4; LED (E) red: Group error; LED (F-H) green/red: Diagnostics
Number of incoming power jumper contacts: 2
Number of outgoing power jumper contacts: 2
Current carrying capacity (power jumper contacts): 10A
Brand |
WAGO |
|
£494.68
per 1 (ex. VAT)£593.62
per 1 (inc. VAT)
Fail-safe 4/4 channel digital input/output - 24 VDC, 2 A, PROFIsafe V2.0 iPar
The 75x-667/000-003 Module is equipped with four power outputs (O1 … O4) and four clock sensitive inputs (I1 … I4). The sensors can be supplied directly with 24 V, or fed by two differently clocked outputs (T1 … T2).
The inputs connect potential-free, emergency-off switches with contacts, safety interlock switches, mode selectors, as well as both safety sensors and semiconductor outputs (e.g., light barriers, PLC outputs). The power outputs switch both DC13 resistive and inductive loads with up to a 2A-rated current without requiring any additional external circuit.
The power outputs operate in both bipolar (high-side/low-side switching) and unipolar (common potential on one side of the load) modes.
The module monitors short circuits, cross circuits and 24 V power supply from separate sources. Both the monitoring and additional safety-relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK.
The configuration tool can be conveniently integrated into engineering systems supporting both CC2 and CC3 tool calling interfaces (TCI).
When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible iPar server – depending on settings. The PROFIsafe address can be set using the DIP switch on the side of the module, or via WAGO-I/O-CHECK.
The module supports both PROFIsafe V1 (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols.
Safety modules can be arranged in any combination when configuring the fieldbus node.
Number of digital inputs: 4
Number of digital outputs: 4
Total number of channels (module): 8
Signal type: Digital, Voltage
Signal type: 24 VDC
Sensor connection: 4 x (Fail-safe input with test pulse)
Input characteristic: clock sensitive
Input characteristic: Type 1 per IEC 61131
Input current per channel for signal (1) typ.: 2.2mA
Output circuit design: Power outputs
Output current per channel: 2A
Output current (module): 8A
Output current: short-circuit-protected
Switching frequency (max.): 50 Hz; Resistive load
Switching frequency (max.) (2): 0.1 Hz; Inductive load
Capacitive load for each channel: O1 … O4; 2.2 µF
Signal frequency (max.): 50Hz
Configuration options: PROFIsafe address adjustable via DIP switch or engineering software
Supply voltage (system): 5 VDC; via data contacts
Current consumption (5 V system supply): 180mA
Supply voltage (field): 24 VSELV/PELV DC (-15 … +20 %); via power jumper contacts (power supply via blade contact; transmission via spring contact)
Current consumption, field supply (module with no external load): 20mA
Isolation: 500 V system/field
Indicators: LED (A-D) green/red: Status/Error I1 … I4; LED (I-M) green/red: Status/error O1 … O4; LED (E) red: Group error; LED (F-H) green/red: Diagnostics
Number of incoming power jumper contacts: 2
Number of outgoing power jumper contacts: 2
Current carrying capacity (power jumper contacts): 10A
Brand |
WAGO |
|